- 物理ホスト
1.イベントの重大度変更機能の有効化
/opt/jp1cons/bin/jcoimdef -chsev ON
/etc/opt/jp1cons/jco_stop
/etc/opt/jp1cons/jco_start
/opt/jp1cons/bin/jco_spmd_status
JP1/IM - Viewを再起動
2.重大度変更定義ファイルを編集
vim /etc/opt/jp1cons/conf/chsev/jcochsev.conf
DESC_VERSION=2
def severity_change001
define enable
addflag false
cnd
B.ID IN 999
end-cnd
sev Emergency
end-def
/opt/jp1cons/bin/jco_spmd_reload
3.動作確認
/opt/jp1base/bin/jevsend -e SEVERITY=Error -m test999 -i 999
→重大度がエラーから緊急に変更を確認
/opt/jp1base/bin/jevsend -e SEVERITY=Error -m test998 -i 998
→重大度がエラーを確認
- 論理ホスト
1.イベントの重大度変更機能の有効化
/opt/jp1cons/bin/jcoimdef -chsev ON -h mmm190
/etc/opt/jp1cons/jco_stop.cluster mmm190
/etc/opt/jp1cons/jco_start.cluster mmm190
/opt/jp1cons/bin/jco_spmd_status -h mmm190
JP1/IM - Viewを再起動
2.重大度変更定義ファイルを編集
vim /mnt/sdc2/im/jp1cons/conf/chsev/jcochsev.conf
DESC_VERSION=2
def severity_change001
define enable
addflag false
cnd
B.ID IN 999
end-cnd
sev Emergency
end-def
/opt/jp1cons/bin/jco_spmd_reload -h mmm190
3.動作確認
/opt/jp1base/bin/jevsend -e SEVERITY=Error -m test999 -i 999 -d mmm190
→重大度がエラーから緊急に変更を確認
/opt/jp1base/bin/jevsend -e SEVERITY=Error -m test998 -i 998 -d mmm190
→重大度がエラーを確認